Patchlage

CVE-2026-64455

CVE CVE-2026-64455EUVD EUVD-2026-48799Published 2026-07-25T08:51:23.000Z

What the advisory describes

In the Linux kernel, the following vulnerability has been resolved: USB: chaoskey: Fix slab-use-after-free in chaoskey_release() The chaoskey driver has a use-after-free bug in its release routine. If the user closes the device file after the USB device has been unplugged, a debugging log statement will try to access the usb_interface structure after it has been deallocated: BUG: KASAN: slab-use-after-free in dev_driver_string (drivers/base/core.c:2406) Read of size 8 at addr ffff888168e8a0b8 by task chaoskey_raw_re/10106 Hardware name: QEMU Ubuntu 24.04 PC v2 (i440FX + PIIX, arch_caps fix, 1996), BIOS 1.16.3-debian-1.16.3-2 04/01/2014 Call Trace: <TASK> dump_stack_lvl (lib/dump_stack.c:94 lib/dump_stack.c:120) print_report (mm/kasan/report.c:378 mm/kasan/report.c:482) kasan_report (mm/kasan/report.c:595) dev_driver_string (drivers/base/core.c:2406) __dynamic_dev_dbg (lib/dynamic_debug.c:906) chaoskey_release (drivers/usb/misc/chaoskey.c:323) __fput (fs/file_table.c:510) fput_close_sync (fs/file_table.c:615) __x64_sys_close (fs/open.c:1507 fs/open.c:1492 fs/open.c:1492) do_syscall_64 (arch/x86/entry/syscall_64.c:63 arch/x86/entry/syscall_64.c:94) entry_SYSCALL_64_after_hwframe (arch/x86/entry/entry_64.S:121) The driver's last reference to the interface structure is dropped in the chaoskey_free() routine, so the code must not use the interface -- even in a debugging statement -- after that routine returns. (Exception: If we know that another reference is held by someone else, such as the device core while the disconnect routine runs, there's no problem. Thanks to Johan Hovold for pointing this out.) Since the bad access is part of an unimportant debugging statement, we can fix the problem simply by removing the whole statement.

Source: EUVD (ENISA), in the words of the advisory.

Products the advisory names

These come from the advisory itself, not from any check we performed.

The versions shown are the advisory's own. Patchlage compares no version numbers and derives no judgement from them — which version is installed is something a person has to look up.

Carried in the product catalogue

An estate covering these products can be recorded in Patchlage. An advisory about them appears in the next morning's situation report.

Does this concern one of your customers?

This page cannot answer that — it does not know your estate. Whoever has recorded their environments gets the answer the morning after publication, together with a paragraph they can forward to the customer unedited.

Try it for 28 days

Patchlage reports hits and suspected hits. About everything else this system says nothing — neither this page nor the situation report ever claims that an estate is safe.